Jet Axial Fan
Jet Axial Fan
Jet Axial Fan
Jet Axial Fan
Jet Axial Fan

Product Features

The Airplus Jet Fan system is seen as a strong alternative to conventional ducted ventilation systems used in indoor parking lots. Thanks to the application, operation and security benefits provided by this system, it has replaced conventional systems. In the design of indoor parking lots, whose daily use and needs are increasing day by day, the ventilation system and fire prevention system are taken into consideration and designed. If the exhaust gases created by the vehicles are not removed from the parking environment at a sufficient level and in a sufficient time, they can cause headaches, fainting and even death in people. These harmful gases and particles are stated as ozone (O3), nitrogen dioxide (NO2), carbon monoxide (CO), benzene (C6H6), benaprin (BaP), sulfur dioxide (SO2), lead (Pb).

Benefits of the AIRPLUS Jet Fan System;

Benefits in Terms of Initial Investment;

• Conventional ducted ventilation systems occupy large areas on the ceiling.

Jet fans provide more usable space since they occupy much less space compared to them.

• It provides a more ergonomic structure and aesthetic appearance for the parking area.

• It requires lower ceiling heights, thus more parking floors can be provided for the same area.

Benefits in terms of design;

• It does not require a conventional duct system that is difficult to design, implement and operate.

• Virtual tests can be performed with CFD analysis for ventilation and fire scenarios, and calculation control can be performed before implementation.

• It is a more effective system with more effective results.

Benefits in terms of operators;

• Thanks to its special 3-piece design, it can be assembled easily and in a shorter time.

Since the silencer sections are connected with a hinged system, service can be provided to the engine and fan without being removed.

• Since there is no need for an additional system, it can be assembled independently of other installation works during application.

• Pressure losses that occur in ducted systems during air movement do not occur. Accordingly, the electrical power required is lower.

• The system is controlled with full automation. Energy savings can be achieved by operating jet fans in required areas with CO (Carbon Monoxide) sensors placed in the parking area.

• It provides more effective air circulation compared to conventional air duct systems.

• In the event of a fire, smoke and high temperatures can be removed in a controlled manner in the safest way.